Review




Structured Review

PentaBase sensiscreen ® egfr liquid assay platform
Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA <t>EGFR</t> analyses.
Sensiscreen ® Egfr Liquid Assay Platform, supplied by PentaBase, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sensiscreen ® egfr liquid assay platform/product/PentaBase
Average 90 stars, based on 1 article reviews
sensiscreen ® egfr liquid assay platform - by Bioz Stars, 2026-05
90/100 stars

Images

1) Product Images from "A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies"

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

Journal: PLoS ONE

doi: 10.1371/journal.pone.0253687

Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.
Figure Legend Snippet: Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.

Techniques Used:

PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.
Figure Legend Snippet: PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.

Techniques Used: Mutagenesis

A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.
Figure Legend Snippet: A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.

Techniques Used: Mutagenesis

Repeatability and accuracy evaluation of  SensiScreen ® EGFR Liquid  assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.
Figure Legend Snippet: Repeatability and accuracy evaluation of SensiScreen ® EGFR Liquid assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.

Techniques Used:

Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.
Figure Legend Snippet: Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.

Techniques Used:

Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus  SensiScreen ® EGFR Liquid assay  (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).
Figure Legend Snippet: Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus SensiScreen ® EGFR Liquid assay (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).

Techniques Used:

Overview of the EGFR phenotypes detected by the  SensiScreen ® EGFR Liquid assay  (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).
Figure Legend Snippet: Overview of the EGFR phenotypes detected by the SensiScreen ® EGFR Liquid assay (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).

Techniques Used: Mutagenesis



Similar Products

90
PentaBase sensiscreen ® egfr liquid assay platform
Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA <t>EGFR</t> analyses.
Sensiscreen ® Egfr Liquid Assay Platform, supplied by PentaBase, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sensiscreen ® egfr liquid assay platform/product/PentaBase
Average 90 stars, based on 1 article reviews
sensiscreen ® egfr liquid assay platform - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
PentaBase sensiscreen® egfr liquid assay platform
Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA <t>EGFR</t> analyses.
Sensiscreen® Egfr Liquid Assay Platform, supplied by PentaBase, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sensiscreen® egfr liquid assay platform/product/PentaBase
Average 90 stars, based on 1 article reviews
sensiscreen® egfr liquid assay platform - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques:

PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques: Mutagenesis

A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques: Mutagenesis

Repeatability and accuracy evaluation of  SensiScreen ® EGFR Liquid  assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Repeatability and accuracy evaluation of SensiScreen ® EGFR Liquid assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques:

Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques:

Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus  SensiScreen ® EGFR Liquid assay  (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus SensiScreen ® EGFR Liquid assay (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques:

Overview of the EGFR phenotypes detected by the  SensiScreen ® EGFR Liquid assay  (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Overview of the EGFR phenotypes detected by the SensiScreen ® EGFR Liquid assay (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).

Article Snippet: In our setup, the SensiScreen ® EGFR Liquid assay platform (PentaBase) outperformed the Therascreen ® platform (Qiagen) and showed 100% agreement at the sequence level to the IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific).

Techniques: Mutagenesis

Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Median age was 65.5 years for cohort I and 69.5 years for cohort II at the time of routine ctDNA EGFR analyses.

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques:

PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: PCR curves obtained when challenging assays with cell lines or plasmids containing the indicated EGFR mutations. Plasmids were diluted 1:1 in WT gDNA to ensure a total template amount of 1600 copies. Reference assay PCR curves are represented by heavy coloured lines and mutation specific assay PCR curves by light coloured lines as indicated in figure legends. Abbreviations: Ct, Cycle threshold; EGFR, Epidermal growth factor receptor.

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques: Mutagenesis

A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: A. Histograms showing the frequency and distribution of mutant copies detected in 102 replicates for assays. B. Boxplot showing the collectively recovered number of copies by the three assays and thereby the overall detected copy number by assays. Abbreviations: EGFR, Epidermal growth factor receptor.

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques: Mutagenesis

Repeatability and accuracy evaluation of  SensiScreen ® EGFR Liquid  assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Repeatability and accuracy evaluation of SensiScreen ® EGFR Liquid assays: Number of copies mutated for Exon 19 deletion, T790M or L858R.

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques:

Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Graphs describing the LoB evaluation based on the characterization of repeated testing of cfDNA pooled from 58 healthy donors A. Curves representing the T790M LoB results. B. Curves representing the L858R LoB results. C. Curves representing the EGFR exon 19 deletion LoB results.

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques:

Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus  SensiScreen ® EGFR Liquid assay  (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Overview of the EGFR phenotypes detected by the Therascreen ® (QIAGEN) versus SensiScreen ® EGFR Liquid assay (Pentabase) and IOT ® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) using cohort I and agreement or disagreement between platforms (N = 34).

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques:

Overview of the EGFR phenotypes detected by the  SensiScreen ® EGFR Liquid assay  (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).

Journal: PLoS ONE

Article Title: A new sensitive and fast assay for the detection of EGFR mutations in liquid biopsies

doi: 10.1371/journal.pone.0253687

Figure Lengend Snippet: Overview of the EGFR phenotypes detected by the SensiScreen ® EGFR Liquid assay (PentaBase ApS) versus the ctEGFR Mutation Detection Kit (EntroGen) using cohort II and agreement or disagreement between platforms (N = 34).

Article Snippet: This motivated us to evaluate the newly developed and commercially available SensiScreen ® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods.

Techniques: Mutagenesis